User Manual
i Series / iX Series 303
9.9.10 Appendix 1: ABD Switching Transients Test Window
Figure 9-69: ABD0100.1.8 Switching Transient Control Window
The ABD0100.1.8 Switching Transients screen provides a high level of control for performing AC
or DC transient tests according to appendix 1 of the ABD0100.1.8. The switching transient tests
are also incorporated in the ABD Table test screen but the parameters for these tests are pre-set
by the test sequence files provided. Using the ABD0100.1.8 Switching Transient control window,
transient parameters can be set interactively and resulting transient timing is displayed
graphically.
Both Figure A (Transparency Tests) and Figure B type transients (Transient Tests) can be
selected and parameter permutations for Figure B tests are automatically generated and
displayed in the transient permutations table above the time domain display.