User Manual
310 i Series / iX Series
Table B:
Apply at 430Hz and 370Hz, Replace
100V & 122V with 23V & 28V
Abnormal Steady State Voltage
Apply for 30 mins iso 5 mins
36.5V for 30ms,16.1V
for 15ms
Use specified limit iso DO160
35.6V for 50ms,18.2V
for 30ms
Use specified limit iso DO160
33.8V for 19.5ms,86V
for 50ms
Use specified limit iso DO160
No undervoltage has to be applied
41.1V for 100ms, 33.8V
for 1 sec
Replace DO160 Fig 16.1 with Fig 4-B
Frequency excursions abnormal
Refer to Appendix 2 for test description